Full 2D, 3D of House Construction Videos
(1) 1st Part
(2) 2nd Part
(3) 3rd Part
This Post will be Updated timely as New Cad videos Uploaded
(1) 1st Part
(2) 2nd Part
(3) 3rd Part
This Post will be Updated timely as New Cad videos Uploaded
Author : Russel Charles Hibbeler
This is most effective book for students and professionals who pursue study and practices in Structural Engineering. The theory and Problems links with practical approaches and real engineering judgements.
Use it for study and Practices only.
American Society for Civil Engineer (ASCE) has published the latest version (ASCE 7-22) for Minimum Design Load and Associated Criteria for Building and Other Structure describes the means for determining design loads including dead, live, soil, flood, tsunami, snow, rain, atmospheric ice, seismic, and wind loads and their combinations for general structural design.
Structural engineers, architects, and building code officials will find the structural load requirements essential to their practice.
Download the Document for Study and Design purpose only.
aci 318-19
American Concrete Institute (ACI) has published the Building Code Requirements for Structural Concrete which is the guide for Reinforced concrete structure while designing the structure. It provides the background of material and rationale for the code provision.
ACI has revised the guide after every 3 years. ACI 318-19 is the latest version. Originally it is made in US but many other countries has followed this document. It has two parts, both are incorporated in this document:
Download this Document only for Study purpose and practical help.
In Civil Engineering it may be on Construction Site while Executing any project or doing calculation in studies or in structural engineering while designing a structures or it may be in any field, it becomes problem when you are not familiar with the basics units. So In this short blog you will be able to convert any units to other unit without memorizing each one. If you know about the most basics unit then you can convert and manipulate bigger units and calculation by just using these concepts.
One thing to remember is if you convert a bigger unit to Smaller one the you have to Multiply with equivalent value and from smaller to bigger one then divide the equivalent value. The following example will clear your concepts.
1st you should know about one linear or dimensional units and these are the basics to convert to any others units if 2D (Area) & 3D(Volume) e.g foot, meters and inches ect if you don’t know about these basics then you can learn it by using a measuring tape (inchi tap). These are basics then you can convert bigger linear units e.g Km, miles etc. You can see here the feets, inches and soot (soother) on the upper part and meters, cm and mm on the lower part horizontally.
So Area is a 2 Dimensional quantity and you can find these units by just squaring of the one dimensional or linear units e.g taking square of m you will got m2 and the same way all other units. It can convert from MKS (meter, kilogram,second) to FPS (Foot,pound Second).
(a)Example: Convert=>5m2 to ft3 => 20m2 = 20 (1*3.28)2 =20*10.76 ft2= 215.2ft2(here using only linear units and converted from bigger to smaller that’s why multiplied)
(b)Example: Convert=>50ft2 => m2 = 50* (1/3.28)2 =50*0.0929 ft2= 4.645m2 (here using only linear units and converted from smaller to bigger units that’s why divide)
Volume is a Three Dimensional Unit and you received that unit by taking cube of 1d units e.g if you take cube of ft then it will become ft3 which is 3d unit. It can be converted any 3d units of MKS(meter, kilogram, second) to FPS(foot,pound, second) with the help of linear units without memorize the exact relation between them.
(b)Example: Convert=> 5m3 to ft3 => 5m3 = 5 (1*3.28)3 =5*35.3 ft3=176.4ft3 (here using only linear units and converted from bigger to smaller that’s why multiplied )
(b)Example: Convert=>40ft3 => m3 = 40* (1/3.28)2 =40*0.028 ft3= 1.12m2 (here using only linear units and converted from smaller to bigger units that’s why divide)
Force,weight and load are same terms used in Civil Engineering and general units used for that is Newton(N), Kg, Pound (lb), KN, Kip(kilo-pound).
If you know about the most basics one e.g 1 Kg=10 N, 1 kg= 2.205 lb then you can convert any units with the help of these tow.
Examples: Convert=>
The same way you can convert things without any single relations known.
So if you have learnt about how to convert forces and 1d(length), 2D(area), 3d(Volume) units then you can easily convert the units of stresses, Densities and Moments/ torques etc.
So we will solve one example for stresses
Examples: Convert=> 1Mpa to Psi
Mpa= N/mm2 and Psi= lb/in2 ; 1 N/mm2 ; So suppose here I don’t know about lb and N relation then taking help of know relations e.g 1 kg = 10 N=> 1 N= 0.1 Kg now replace the kg by pound (lb) because we know that relation; 1 N= 0.1 ( 2.205 lb)=> 1N= 0.2205 lb and the same way convert mm2 to in2 => suppose we don’t know the relations between mm to in then; 1mm2= (1/1000)2 = 1o-6 m2; converted into meters because we know the relation between meter to ft; 10-6 (3.28)2 ft2 = 0.00001076 ft2 now convert that feets to inches; 0.00001076*(12)2 in2= 0.001549 in2 .
Now put the values of 1 N= 0.2205 lb and 1mm2= 0.001549 ; 1 N/mm2(MPa)= 0.2205 lb/0.001549 in2 (Psi)=> 1 N/mm2=143 Psi but exactly it is equal to 145 Psi as I put values approximately.
so from the above example you may have cleared that only know the basics concepts you can derive any units.
Watch the Video given below I have discussed it briefly;
==========Thank You==========
Definition: “The RCC Section which is reinforced with such amount of steel that when extreme fiber of compression zone of concrete reaches to its permissible allowable stress and strain value (ϵc =0.0035 and fc=0.45fck), the steel provided in tension zone also reaches to its permissible yield allowable strain and stress value (ϵst= (0.002+(0.87fy/Es)) and fs= 0.87fy) at same time then that section will be a Balanced or Critical Section.”
(Moment of Resistance) Mr= Compressive Force*(d-0.42d)
or Mr= Tensile Force*(d-0.42d)
Definition: “The RCC Section which is reinforced with such amount of steel that when extreme fiber of concrete in compression zone reaches to its permissible allowable Strain and stress value(ϵc =0.0035 and fc=0.45fck), while the allowable stresses in steel provided in tension zone doesn’t reaches to its permissible allowable yield strain and stress(ϵst= (0.002+(0.87fy/Es)) and fs= 0.87fy) then that section will be an Over-Reinforced Section.”
(Moment of resistance) Mr=b.n.(fst/2) *(d-n/3)
Definition: “The RCC Section which is reinforced with such amount of steel that when extreme fiber of concrete in compression zone doesn’t reach to its permissible allowable strain and stress value(ϵc =0.0035 and fc=0.45fck), while the allowable stresses in steel provided in tension zone doesn’t reaches to its permissible allowable yield strain and stress(ϵst= (0.002+(0.87fy/Es)) and fs= 0.87fy) then that section will be an Under-Reinforced Section.”
This is the most desirable section(Under-Reinforced) because:
(Moment of Resistance) Mr=fst.Ast(d-n/3)
Note: Now You can evaluate Neutral Axis by the sections given below:
Watch the video… if still any any Query you can comment…Thank You
You may have noticed that normally on construction site, the mix ratio of concrete has been already mention in construction drawings. So you have to follow that ratio of concrete. That concrete will give you a concrete strength of ordinary strength normally from M5(1:5:10) to M25(1:1:2). The magnitude mention with the letter M mean the Compressive strength of concrete which in in N/mm2 or Megapascal(Mpa). You can see some Nominal Mix ratios in the table given below.
So this is about the nominal mix when you have to follow the already fix ratios regardless of the material specific properties. This is normally used for residential or other commercial structures where there is no need of high strength concrete.
So the Design mix of concrete is done for high strength of concrete. When…
View original post 238 more words
You may have noticed that normally on construction site, the mix ratio of concrete has been already mention in construction drawings. So you have to follow that ratio of concrete. That concrete will give you a concrete strength of ordinary strength normally from M5(1:5:10) to M25(1:1:2). The magnitude mention with the letter M mean the Compressive strength of concrete which in in N/mm2 or Megapascal(Mpa). You can see some Nominal Mix ratios in the table given below.
So this is about the nominal mix when you have to follow the already fix ratios regardless of the material specific properties. This is normally used for residential or other commercial structures where there is no need of high strength concrete.
So the Design mix of concrete is done for high strength of concrete. When the strength requirements beyond M25 (25 Mpa) strength of concrete and when the structures strength is the primary priority then you have to go for Mix Design of concrete.
In Mix Design of Concrete you have to check every material (Aggregates, Water, Admixtures etc) properties that you have to use in your concrete mix and upon some trial you have got the desired strength with some mix ratios. So that Mix proportion of concrete ingredients should be noted with the respective strength. For this you have to bring all the samples of your materials (Aggregates, fine Aggregates, water etc) ingredients to the Mix Ratio Laboratory of your specific area from where you considered to use the concrete ingredients Source. If you want to change the source of the concrete ingredients during construction, then again you to go for mix design. Then that will be your Design Mix ratio for concrete that you have to follow for that specific structures and specific projects. Some Examples of Mix Design ratios or given in the table below but you cannot follow it directly on your site and you to do your own MIX Design for the Concrete ingredients that you have to use in your project. So the values given in table for mix design is M30 to M70.
Thank You if you have still any doubts, you can ask in comment.
After reading this blog, you will be able to identify and can execute different types of support in real structure in construction site.
During Engineering you have shown just the idealized form of supports but when you go to construction site you cannot identify and execute different type support in real structures. So in this article your confusion will be vanished. Here we have discussed the most important three (3) types of supports normally used and cause confusion.
Fixed support mean that it can resist and restrain all the possible movement (vertical, horizontal & bending moment) through the joint/support and the stresses generate in beam due to any type of loading can transfer from beam to column safely. Now we discuss fixed support in Reinforced Cement Concrete Structures (RCC) and Steel Structures:
In RCC structure first column concrete is done upto beam bottom level and then after fixing the reinforcements of beam and slab with the column projected rebars then concrete it monolithically so that the member can act as a fixed unit. To identify that the support is fixed or hinged/pin in RCC beam-column joint or the column jointed with foundation, you must check the rebar detail in drawing and on site that if proper development length(Ld) is provided then and the desired ratio of concrete is followed at the site then the support will be consider is fixed. Because the reinforcement at the support will tell you about whether the support is fixed or hinged/pin. The proper development length (Ld) and required concrete grade will achieve sufficient bond/anchorage at that at that joint to resist all the stresses. This type of support is mainly designed to resist bending moment along with the other stresses. You can see the fixed support in the figure below:
The phenomena of fixed support that it will resist the possible movements will be same as in the RCC structures. The Steel Beam-Column connections or column-footing connections will be considered as fixed if the bolts or welds around the joint (around the flange and web) are fixed/applied throughout along with gusset plates at that joint/support. If the bolts or welds are fixed/applied only at the web section then it will consider as a hinged/pinned support because it will not resist all the movements (vertical, horizontal or bending moment) except the few one. This type of support is mainly designed to resist bending moment along with the other stresses. Through this type of bolting/welding you provided sufficient anchorage to resist all the stresses. The steel has to resist all the tension not concrete. You can see the Fixed Support in Steel Structure in figure/image below:
In this type of support only the horizontal and vertical movements are restrained but cannot resist bending moment. This type of support are not designed for taking any bending moments but just take the axial stresses (axial compression and axial tension). That’s why this type of support is mainly provided only in trusses. But if the bending is not the failure criteria of any member or if the bending moment is not generate sufficiently in any support that it can fail then we provide it in RCC and Steel Frames also:
You may have seen that in residential buildings or low storey buildings in which the load bearing component is brick walls then the beams and columns provided there by the unefficient contractor at some areas or in the whole structures is which may be not needed at all and also the structure is not properly designed by the structural engineer. If you look upon the reinforcement at beam-column joints or column-footing joints then you will find that they are not provided any development length or may be not sufficient to developed the required bond/anchorage at the joint. Because the tension is resisted by the steel not concrete. The concrete is also of very low Grade, so that support will not be considered as fixed but it will be a Hinge/Pin Support. But the loads are mainly taking by brick masonry walls that’s why the structure is stable. But you cannot allow this type of supports in RCC frame structures where the load bearing element is beam-column. You can see in given figure:
As we have discussed earlier that This type of support are not designed for taking any bending moments but just take the axial stresses (axial compression and axial tension). That’s why this type of support is mainly provided and designed for trusses. But it can be provide in Steel frames Beam-Column and Column-Footing joints when the bending is not the failure criteria. In this type of beam-column joints or column-footing joints the bolts/welds provided only at the web section or flange section of that element which is sufficient to resist the axial stresses. You can see in given figure below:
Roller support can resist only vertical forces. So it is provided only when there is only axially compressive forces are there. You have seen the simply supported beams/girders may be of Steel or RC. The idealized form of simply supported beam is one side is hinge and the other is roller (see image). We consider it because at the hinge/pin side of beam resist horizontal forces because lateral movement are not generate at the element just because of hinge/pin and the other side is roller because due to temperature changes and heavy loads there may be little lateral bit forces occur which causes expansion and bending. If we consider both side is hinged then the temperature stresses in element will cause beam to crack and if we consider both side is roller than little component of lateral force can cause beam/girder to move horizontally which will be unstable. So when the beam which may be RCC or Steel which is lies just on both side support may be brick wall or RCC column but not casted monolithically then that will be an example of simply supported in which one side is roller and the other is hinge/pin support. You can see the roller support both in Steel and RCC structure given below:
Watch the short video given below under these discussion Topics:
Following are some of the important Factors and criteria regarding One-Way Slabs:
Following are some of the important Factors and criteria regarding One-Way Slabs: